Lucent Technologies PortMaster User Manual
Page 97

Configuring an Asynchronous Port
5-21
Configuring a Port for a Dedicated Connection
To configure a port for a hardwired connection, follow this procedure:
1.
Set the port for network hardwired.
Command> set S0 network hardwired
2.
Set the protocol.
Command> set S0 protocol slip|ppp
3.
Set the maximum transmission unit (MTU) size.
Command> set S0 MTU MTU
4.
Set the destination IP address.
Command> set S0 destination Ipaddress
[Ipmask]
5.
Set the IPX network number if you are using IPX.
Command> set S0 ipxnet Ipxnetwork
6.
Enable RIP routing.
Command> set S0 rip on|off|broadcast|listen
7.
Set compression.
Command> set S0 compression on|off|stac|vj
8.
Set the PPP asynchronous map (if required).
Command> set S0 map Hex
9.
Set input and output filters (if using).
Command> set S0 ifilter [Filtername]
Command> set S0 ofilter [Filtername]
Omitting the Filtername removes any filter previously set on the port.
10. Save the configuration.
Command> save all
11. Reset the port.
Command> reset S0