Lucent Technologies PortMaster User Manual
Page 282

Configuration Steps for Shared Device Access
18-6
PortMaster Configuration Guide
Leave all other settings at their default values.
After you configure port S2 as shown in Table 18-3, enter the following commands to
reset the port and save the configuration:
Command> reset s2
Command> save all
For more information about serial asynchronous ports, refer to Chapter 5, “Configuring
an Asynchronous Port.”
Speed 1
set s2 speed 1 115200
Speed 2
set s2 speed 2 115200
Speed 3
set s2 speed 3 115200
Modem control
set s2 cd on
Hardware flow control
set s2 rts/cts on
Software flow control
set s2 xon/xoff off
Host
set s2 host default
Security
set s2 security on
(If you turn security on, you must also configure the user
table or RADIUS.)
Login service
set s2 service_login portmaster
Device service
set s2 service_device portmaster
Table 18-3
Serial Port Values (S2) (Continued)
Setting
Command