Configuring global settings, Configuring ethernet interface settings – Lucent Technologies PortMaster User Manual
Page 292

Configuration Steps for Leased Line Connections
19-6
PortMaster Configuration Guide
Configuring the PortMaster Office Router in Florence
Configure the settings for the PortMaster Office Router in Florence with the values in
the following sections.
Configuring Global Settings
Configure the global settings to the values shown in Table 19-4.
After you configure the global settings shown in Table 19-4, enter the following
command to save the configuration:
Command> save all
For more information about global settings, refer to Chapter 3, “Configuring Global
Settings.”
Configuring Ethernet Interface Settings
Configure the Ethernet settings to the values shown in Table 19-5.
Table 19-4
Global Values
Setting
Command
IP gateway
set gateway 192.168.200.1
System name
set sysname office2
Table 19-5
Ethernet Values
Setting
Command
IP address
set ether0 address 192.168.1.1
Netmask
set ether0 netmask 255.255.255.0
IPX network
set ether0 ipxnet F1
IPX frame type
set ether0 ipxframe ethernet_802.2
Broadcast address
set ether0 broadcast high
RIP routing
set ether0 rip on