Portmaster serial interfaces – Lucent Technologies PortMaster User Manual
Page 55

Configuring Global Settings
3-17
Configuring SNMP
The SNMP manager queries the agents by means of OIDs. Each OID uniquely identifies
a single MIB variable. For example, the OID 307.3.2.1.1.1.2.0, returns the portname for
port S0, and the OID 307.3.2.1.1.1.2.1 returns the port name for port S1 (see Table 3-5).
Table 3-5
Partial View of the Livingston Serial Table.
PortMaster Serial Interfaces
Table 3-6 lists the objects in the serial interface table from the Livingston Extensions
section of the MIB. Modem-specific objects apply to the PortMaster 3 only.
OID
S0
(0) S1
(1)
S2
(2)
S3
(3)
S4
(4)
...307.3.2.1.1.1.1
Index
Index
Index
Index
Index
...307.3.2.1.1.1.2
PortName
PortName
PortName
PortName
PortName
...307.3.2.1.1.1.3
PhysType
PhysType
PhysType
PhysType
PhysType
...307.3.2.1.1.1.4
User
User
User
User
User
...307.3.2.1.1.1.5
SessionId
SessionId
SessionId
SessionId
SessionId
...307.3.2.1.1.1.6
Type
Type
Type
Type
Type
...307.3.2.1.1.1.7
Direction
Direction
Direction
Direction
Direction
Table 3-6
Serial Interfaces Table
Object
Definition
Index
Unique value for each serial interface.
PortName
Text string containing the name of the serial interface (for
example, S0, W1, and so on).
PhysType
Type of physical serial interface, distinguished according to
the physical or link protocol(s) currently being used on the
interface.
User
Name of the active user. Blank if not active.
SessionId
Unique session identifier that matches the RADIUS session
ID.
Type
Active type of service being provided by the serial interface.