Configuration Steps for a Synchronous V.25bis Connection
14-8
PortMaster Configuration Guide
Configuring Global Settings
Configure the following global settings to the values shown in Table 14-6.
After you configure the global settings shown in Table 14-6, enter the following
command to save the configuration:
Command> save all
For more information about global settings, refer to Chapter 3, “Configuring Global
Settings.”
Configuring Ethernet Interface Settings
Configure the Ethernet settings to the values shown in Table 14-7.
Table 14-6
Global Value
Setting
Command
IP gateway
set gateway 192.168.1.2
(This is the address of the next upstream router.)
Default routing
set default on
System name
set sysname miami
Table 14-7
Ethernet Values
Setting
Command
Protocol
set ether0 ipx enable
IP address
set ether0 address 192.168.1.1
Netmask
set ether0 netmask 255.255.255.0
IPX network
set ether0 ipxnet F2
IPX frame type
set ether0 ixpframe ethernet_802.2
Broadcast address
set ether0 broadcast high
RIP routing
set ether0 rip on