Configuring the office router in london, Configuring the office router in london -4, Configuring global settings – Lucent Technologies PortMaster User Manual
Page 240: Configuring ethernet interface settings

Configuration Steps for an Office-to-Office Connection
15-4
PortMaster Configuration Guide
Configuring the Office Router in London
Configure the following settings on the PortMaster PCMCIA Office Router in the
London office to enable London office users to access the main office network in Paris
on demand.
Configuring Global Settings
Configure the global settings shown in Table 15-1. The values shown in the table only
apply to this example. When you are configuring your PortMaster, use values
appropriate for your network.
After you configure the global settings shown in Table 15-1, enter the following
command to save the configuration:
Command> save all
For more information about global settings, refer to Chapter 3, “Configuring Global
Settings.”
Configuring Ethernet Interface Settings
Configure the Ethernet settings shown in Table 15-2.
Table 15-1
Global Values
Setting
Command
IP gateway
set gateway 192.168.1.1
System name
set sysname london
Table 15-2
Ethernet Values
Setting
Command
IPX network
set ether0 ipxnet F3
IPX frame type
set ether0 ipxframe ethernet_802.2
IP address
set ether0 address 192.168.200.1
Netmask