Configuring global settings, Configuring ethernet interface settings – Lucent Technologies PortMaster User Manual
Page 226

Configuration Steps for a Synchronous V.25bis Connection
14-4
PortMaster Configuration Guide
Configuring Global Settings
Configure the global settings to the values shown in Table 14-1.
After you configure the global settings shown in Table 14-1, enter the following
command to save the configuration:
Command> save all
For more information about global settings, refer to Chapter 3, “Configuring Global
Settings.”
Configuring Ethernet Interface Settings
Configure the Ethernet interface settings to the values shown in Table 14-2.
After you configure the Ethernet interface as shown in Table 14-2, enter the following
command to save the configuration:
Command> save all
Table 14-1
Global Values
Setting
Command
IP gateway
set gateway 192.168.1.1
System name
set sysname boston
Table 14-2
Ethernet Values
Setting
Command
IP address
set ether0 address 192.168.200.1
Netmask
set ether0 netmask 255.255.255.0
IPX network
set ether0 ipxnet F1
IPX frame type
set ether0 ipxframe ethernet_802.2
Broadcast address
set ether0 broadcast high
RIP routing
set ether0 rip on