beautypg.com

Troubleshooting – Seiko Instruments SII Black-and-White Raster Plotter LP-1020 User Manual

Page 218

background image

14-2

Troubleshooting

Before calling your dealer or our service center, check the following

items and take corrective measures.

■Items to be checked

Note

Symptom

Items to be checked

Corrective measure

No power

Power cable connection

Plug the power cable into the outlet correctly.

Power supply to the outlet Supply the power to the outlet.

Failure to start or
operate correctly

ERROR llights and LC
message display

Take appropriate measures according to the

error message.

⇒Page 14-3

Failure to plot

Interface cable connection

Connect the interface cable correctly.

ERROR lights and LC
message display (See

"

Note" below)

Take appropriate measures according to the

error message.

⇒Page 14-3

Failure to plot
transmitted data
immediately

DATA lghts
(on or flashing?)

Review the time-out setting.

Frequent paper

jam

Paper type

Check whether the paper type setting matches
the type of the loaded paper.

⇒Page 7-2

Use our recommended paper.

⇒Page 1-7

Paper roll

Load the paper correctly.

⇒Page 2-16

Check whether there is
any foreign material in
the paper path

Remove any foreign material.

( "Paper Jam"

⇒Page 14-3)

◆ In case of a communication warning or data error, the

ERROR lamp does not light. Also, an error message,

even if displayed, will disappear when the next operation

is performed.

If a problem occurs between the computer and the device

immediately after the line connection, check the LCD for

presence of a communication warning (⇒ page 14-20) at
the time of transmission of data to the device.

For a data error, an error message can be printed on the

drawing (⇒ page 14-22).