Figure 3-2. fibre channel cable connector -4, List, Figure 3-2 on – StorageTek 9840 User Manual
Page 54

Inspecting the Equipment
3-4
Sixth Edition
95741
Note: The cable connector is keyed so the cable can only be inserted one way.
The cable acts somewhat like a null modem cable in that the transmit from one
end of the cable connects to the receive at the other end of the cable. The cable
connectors are typically labeled A and B. In addition, one strand of the cable is
labeled (with the vendor name and other information) while the other strand is
unlabeled.
Table 3-1. Fibre Channel Cable (SC to SC Connectors) Part Numbers
Length
Part Number
Meters
Feet
Plenum
1
Riser
2
2
6.6
10800122
10800132
5
16.4
10800123
10800133
10
32.8
10800124
10800134
20
65.6
10800125
10800135
30
98.4
10800126
10800136
50
164
10800127
10800137
100
328.1
10800128
10800138
250
820.2
10800129
10800139
500
1640.4
10800130
10800140
Notes:
1. Plenum cables are designed for installation in air ducts. Plenum materials are
manufactured to meet UL standards for flammability (produce little smoke).
2. Riser cables can be used in computer rooms. Riser cable materials are not classified
according to flammability or toxic gas emissions.
Figure 3-2. Fibre Channel Cable Connector
C53685