Drive Operations Menu
6-36
Sixth Edition
95741
Code Update Submenu
IPL FromTP
IPL From Tape, updates the
drive firmware from a firmware
tape inserted in the drive.
If a normal tape is present in
the drive when this function is
activated, it ejects.
When the update is done, the
drive automatically ejects the
firmware tape, performs IPL,
and goes Online.
If
CodUpFailsx
(Code
Update Fail Number x) or
CHK xxxx
displays, refer to
for
instructions.
1. Press
Menu
to bypass, or
2. Press
Select
to activate.
3. When
Ld IPL Tp
displays, insert
the write-protected firmware tape
containing the desired code level.
Dump Tape Submenu
MakeDumpTp
Make Dump Tape, formats a
tape; but, it does not collect
diagnostic data. Tapes used to
obtain dump data must first be
formatted this way to accept
dump data.
If a normal tape is present in
the drive when this function is
activated, it ejects.
Old data on tape being
formatted will be erased.
If
DmpCrFailx
(Dump Create
Fail Number x) or
CHK xxxx
displays, refer to
for instructions.
1. Press
Menu
to bypass, or
2. Press
Select
to activate.
3. When
Ld Dump Tp
displays, insert
a write-enabled tape.
4. When the tape ejects, insert another
tape, or press
Menu
to advance to
the next submenu.
Table 6-3. Menu Table—Drive Operations (Continued)
Options
Notes
Procedure