StorageTek 9840 User Manual
Page 36

Operator Panels
1-12
Sixth Edition
95741
clean
(amber)
On (steady):
Drive requires cleaning because of:
1. Distance, when a firmware defined length of
tape has passed over the R/W heads.
2. Error, after a read/write perm and at least half
the firmware defined length of tape has passed
over the R/W heads.
service
(red)
Off:
Flashing:
On (steady):
No error was detected.
An error/s detected and dump data is being
collected to the EEPROM.
If within one minute the drive detects the same
FSC, the message
DumpAgain?
is displayed: see
“DumpAgain? Indication” on page 7-12
for
instructions.
A hardware error was detected and drive is not
functional. A constant indicator cannot be
ignored by the operator. If a manually initiated
IPL doesn’t eliminate problem, the drive should
be replaced.
Table 1-3. Operator Panel Indicators (Continued)
Indicator
Name
Indication
Explanation