StorageTek 9840 User Manual
Page 201
![background image](/manuals/135996/201/background.png)
95741
Sixth Edition
7-5
Dislodge a Stuck Tape
CodUpFail3
The tape format is
unreadable.
Reclaim as a data tape, recreate code tape.
Retry the operation.
Try another tape.
Note: In code level 1.30.109 and up, error message is replaced by
CHK xxxx
.
CodUpFail4
This is not a code-update
tape.
Retry with the correct tape.
Note: In code level 1.30.109 and up, error message is replaced by
CHK xxxx
.
DatCrFail1
Unable to create (format) a
data tape.
Make sure the tape is write-enabled.
Try another drive or CSL.
Note: In code level 1.30.109 and up, error message is replaced by
CHK xxxx
.
DmpCrFail1
Unable to create (format) a
dump tape.
Make sure the tape is write-enabled.
Try another tape.
Try another drive or CSL.
Note: In code level 1.30.109 and up, error message is replaced by
CHK xxxx
.
DmpCrFail2
The tape format is
unreadable.
Reclaim as a data tape.
Retry the operation.
Try another tape.
Note: In code level 1.30.109 and up, error message is replaced by
CHK xxxx
.
DumpToHost
The dump or event log is
being transferred to host; the
operator panel switches are
locked
No action necessary.
DmpWrFail1
Unable to write a dump to
tape.
Unable to position on tape.
Try another tape.
Make sure the tape is formatted for a
dump.
Note: In code level 1.30.109 and up, error message is replaced by
CHK xxxx
.
DmpWrFail2
No dump to process.
Force a diagnostic dump.
Note: In code level 1.30.109 and up, error message is replaced by
CHK xxxx
.
DumpAgain?
The drive or CSL detected the
same “CHK (xxxx)” within
one minute.
Go to
.
Exp ClCart
The cleaning cartridge is used
up.
Replace the cleaning cartridge.
Table 7-2. Error Displays and Instructions (Continued)