StorageTek 9840 User Manual
Page 170
Fibre Channel Change Configuration
6-14
Sixth Edition
95741
Compress Mode Submenu
Cmprss Yes
Cmprss Off
Cmprss No
Defaults to last saved selection.
When
Yes
is selected, data is
compressed, by default. Host can
request no data compression.
When
Off
is selected, data is not
compressed, and host request has
no effect.
When
No
is selected, data is not
compressed, by default. Host can
request data compression.
1. Press
Menu
to bypass, or
2. Press
Select
until the desired
option is displayed; then, press
Menu
to set, and advance to next
submenu.
Note: Manufacturing ships drive with the Cmprss Yes
option
selected.
Data Security Erase Mode Submenu
Full DSE Y
Full DSE N
Defaults to last saved selection.
Full DSE Y
writes a random
binary pattern on the media,
over-writing existing data, from
the point of an “Erase” command,
to the End of Tape.
Full DSE N
writes data on the
media that indicates valid data
does not exist beyond the point
of an “Erase” command.
1. Press
Menu
to bypass, or
2. Press
Select
to toggle option;
then, press
Menu
to set, and
advance to next submenu.
Note: Manufacturing ships drive with the
Full DSE Y
option
selected.
Port A Attributes Submenu
Cfg PrtA ?
View or change Port A attributes
as defined in the Port A/B
Attributes Submenus.
1. Press
Select
(Yes) to enter the
Port A/B Attributes submenus, or
2. Press
Menu
(No) to bypass.
Port A/B Hard Physical Addressing Submenu
Hard PA N
Hard PA Y
Defaults to last saved selection.
PA N
uses a new physical
address each time.
PA Y
uses same assigned
physical address each time.
1. Press
Menu
to bypass, or
2. Press
Select
to toggle option;
then, press
Menu
to set, and
advance to next submenu.
Note: Manufacturing ships drive with Hard PA N option
selected.
Table 6-1. Menu Table—Fibre Channel Configuration (Continued)
Options
Notes
Procedure