English

General settings

How to set

68

L

1

DISK1

Displays the total capacity of the internal hard disk. If the
hard disk is replaced, the capacity may change.

2

DISK2

Displays the total capacity of the second hard disk, if it was
installed in the DVR.

3

DISK INITIALIZE

This item is used to initialize the internal hard disk. All
recordings are erased when the hard disk is initialized.

The initialization is performed on DISK1 and DISK2
simultaneously.

4

MIRRORING

If another hard disk is installed, and MIRRORING is turned
"ON", then a PLAYBACK DRIVE can be selected, and the
same video will be recorded on both hard disks. If a writing
error occurs, one of DISK1 and DISK2 can be used to read
the recordings.

• Note that if MIRRORING is turned "ON", the recording

rate will be automatically limited (to half of the normal
recording rate).

• If a playback problem occurs while MIRRORING is ON,

change the hard disk used for playback by selecting
DISK1 or DISK2 at the "PLAYBACK DRIVE" setting.

5

PLAYBACK DRIVE

Use this setting together with MIRRORING, to designate
one of the two hard disks for video playback.

Selections: DISK1/DISK2

1

Display the screen using "Displaying
the general settings screen". (P62)

The cursor moves to "DISK INITIALIZE".

2

Turn the S-dial clockwise.

The screen is displayed, and "NO" is
blinking.

3

Turn the J-dial, select "YES", and turn the S-dial
clockwise.

The "HDD INITIALIZING !" message appears, and the
initialization starts.

When the initialization is complete, the
screen returns.

4

Press the EXIT/OSD button.

D

Hard disk settings menu description

b Hard disk expansion

Before installing another hard disk, consult with the store where
you purchased your system.

We recommend using the expansion hard disk provided by
SANYO. Operation is not guaranteed if a hard disk other than
SANYO's recommended type is used for capacity expansion.

• The hard disks must be initialized, upon installing an

expansion disk. The initialization is performed on the two hard
disks simultaneously. Save your recordings on a
CompactFlash card or other media before the initialization.

DISK1 : 82GB

DISK2 : ---GB

DISK INITIALIZE ->

CAUTION : ALL RECORDING WILL BE ERASED!

MIRRORING : OFF

PLAYBACK DRIVE : ***

CAUTION : RECORDING SPEED WILL BE

LIMITED BY MIRRORING!

1
2
3

4
5

D-1

Hard disk initialization

MENU

(J)

(S)

DISK1 : 82GB

DISK2 : ---GB

DISK INITIALIZE ->

CAUTION : ALL RECORDING WILL BE ERASED!

4.HDD SET

3.GENERAL SET

HDD INITIALIZING !

THIS CHANGE WILL INITIALIZE THE DISK.

ALL RECORDING WILL BE ERASED.

ARE YOU SURE ?

NO

CHANGE:JOG SET:SHUTTLE

EXIT/OSD