background image

E55

Menu item

DETAIL

LEVEL

LEVEL DEP

FREEZE screen

PROCESS (1/3) screen

Menu item

CANCEL

Function/variable range

Used to set the cancellation method of freeze.
MANUAL: freeze is cancelled by pressing the FREEZE

button.

AUTO:

freeze is automatically cancelled.
The figures in parentheses denote the approxi-
mate time (sec) until automatic release.
Pressing the FREEZE button before automati-
cally cancel will repeat the freeze.

Default value

MANUAL

Function/variable range

Used to set whether to emphasize details.
ADJUST: changes the detail emphasis
OFF:

no detail emphasis

The emphasis level of the detail is adjusted when DETAIL
is set to ADJUST.
Sharpen the detail: increase the number
Soften the detail:

decease the number

[Variable range: –7 ~ 7]

Adjusted when you want to reduce noise in black areas.
Noise in black areas is reduced because the frequency
characteristics of areas where the image signal level falls
below this set value are lowered. However, fine details in
areas falling below the set value will be lost.
[Variable range when ON: 0.0% ~ 28.5% (changeable in
0.5 steps)]

Default value

ADJUST

0

0.0%

(1s)
(3s)
(5s)

MEMO

The setting value is the value to be set for the input signal