McDATA 4300 User Manual
Page 181

Event Code Tables
A-41
Event Code Tables
Event Code: 812
Message:
CTP card shutdown due to thermal violations.
Severity:
Major.
Explanation:
The CTP card failed due to excessive thermal violations. This event follows an event code 811.
Action:
Perform a data collection and return the CD to support personnel. Perform a switch reset. If the problem persists,
replace the switch.
Event Data:
No supplementary data included.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
✔
✔
✔
Event Code: 850
Message:
Switch shutdown due to CTP thermal violations.
Severity:
Severe.
Explanation:
The switch failed due to excessive CTP card thermal violations.
Action:
Perform a data collection and return the CD to support personnel. Perform a switch reset. If the problem persists,
replace the switch.
Event Data:
No supplementary data included.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
✔
✔
✔