McDATA 4300 User Manual
Page 179

Event Code Tables
A-39
Event Code Tables
Event Code: 585
Message:
Primitive sequence timeout.
Severity:
Major.
Explanation:
An attached server recognized either a link reset (LR) protocol timeout or a timeout while waiting for the
appropriate response (while in a NOS receive state and after NOS was not longer recognized).
Action:
A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI).
If fault isolation at the server does not detect a failure, the problem may be due to a port failure. Go to
to perform fault isolation. In addition, perform a data collection and return the CD to support personnel.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
✔
Event Code: 586
Message:
Invalid primitive sequence received for current link state.
Severity:
Major.
Explanation:
An attached server recognized either a link reset (LR) or a link-reset response (LRR) sequence while in the
wait-for-online sequence (OLS) state.
Action:
A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI).
If fault isolation at the server does not detect a failure, the problem may be due to a port failure. Go to
to perform fault isolation. In addition, perform a data collection and return the CD to support personnel.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
✔