McDATA 4300 User Manual
Page 145

Event Code Tables
A-5
Event Code Tables
Event Code: 062
Message:
Maximum interswitch hop count exceeded.
Severity:
Informational.
Explanation:
Fabric controller software detected a path to a director or switch that traverses more than seven interswitch links
(hops). This may result in Fibre Channel frames persisting in the fabric longer than timeout values allow.
Action:
Reconfigure the fabric so the path between any two switches traverses seven or less ISLs.
Event Data:
Byte 0 = domain ID of the director or switch more than seven hops away.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
✔
Event Code: 063
Message:
Remote switch has too many ISLs.
Severity:
Major.
Explanation:
The director or switch with domain ID indicated in the event data has too many ISLs attached and is unreachable
from this switch.
Action:
Reduce the ISLs on the indicated director or switch to a number within limits specified.
Event Data:
Byte 0 = domain ID of the director or switch with too many ISLs.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
✔
✔