Thermal sensor events (800 through 899) – McDATA 4300 User Manual
Page 180

A-40
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Event Code Tables
Thermal Sensor Events (800 through 899)
Event Code: 810
Message:
High temperature warning (CTP card thermal sensor).
Severity:
Major.
Explanation:
The thermal sensor associated with the CTP card indicates the warm temperature threshold was reached or
exceeded.
Action:
Perform a data collection and return the CD to support personnel. Perform a switch reset. If the problem persists,
replace the switch.
Event Data:
No supplementary data included.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
✔
✔
✔
Event Code: 811
Message:
Critically hot temperature warning (CTP card thermal sensor).
Severity:
Major.
Explanation:
The thermal sensor associated with the CTP card indicates the hot temperature threshold was reached or
exceeded.
Action:
Perform a data collection and return the CD to support personnel. Perform a switch reset. If the problem persists,
replace the switch.
Event Data:
No supplementary data included.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
✔
✔
✔