McDATA 4300 User Manual
Page 172

A-32
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Event Code Tables
Event Code: 508
Message:
Fibre Channel port anomaly detected.
Severity:
Informational.
Explanation:
The switch detected a deviation in the normal operating mode or status of the indicated Fibre Channel port.
Action:
No action required. An event code 506 is generated if this anomaly results in a hard port failure.
Event Data:
Byte 0 = port number.
Byte 12 = detecting port.
Byte 1 = anomaly reason code.
Byte 13 = connected port.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 16 and 17 = HA error callout #3.
Bytes 8 and 9 = HA error callout #1.
Bytes 18 and 19 = HA error callout #4.
Bytes 10 and 11 = HA error callout #2.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
✔
Event Code: 510
Message:
Optical transceiver hot-insertion initiated.
Severity:
Informational.
Explanation:
Installation of an optical transceiver was initiated with the switch powered on and operational. The event indicates
operational firmware detected the presence of the transceiver.
Action:
No action required.
Event Data:
Byte 0 = port number.
Byte 2 = optic type.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 - 11 = optic serial number.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
✔