Event Code Tables
A-21
Event Code Tables
Fan Events (300 through 399)
Event Code: 300
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
One cooling fan failed or is rotating at insufficient angular velocity.
Action:
Replace the switch.
Event Data:
The first byte of event data (byte 0) specifies the failed fan number.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
✔
✔
✔
Event Code: 301
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Two cooling fans failed or are rotating at insufficient angular velocity.
Action:
Replace the switch.
Event Data:
The first byte of event data (byte 0) specifies the failed fan number(s).
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
✔
✔
✔