13 lcd controller timing, Lcd controller timing -17 – Motorola MC68VZ328 User Manual
Page 333

AC Electrical Characteristics
Electrical Characteristics
19-17
19.3.13
LCD Controller Timing
Figure 19-13 shows the LCD controller timing diagram for normal mode, and Figure 19-14 on page 19-18
displays the timing diagram for self-refresh mode. The signal values and units of measure for both figures
are found in Table 19-15 on page 19-18. Detailed information about the operation of individual signals can
be found in Chapter 8, “LCD Controller,” and Chapter 7, “DRAM Controller.”
Figure 19-13. LCD Controller Timing Diagram (Normal Mode)
9
RASx pulse width
(2N + 1)T
—
ns
10
CASx
pulse width (BC[1:0] = 00,01,10,11 in FPM)
28,58,88,118
—
ns
11
CASx
precharge time
26
—
ns
12
RASx negated to CASx negated
-28
—
ns
13
Data-in hold after CASx
negated
0
—
ns
14
OE negated after CASx
negated
0
2
ns
Note:
N is the number of words in one DMA transfer.
T is the system clock period.
RASx stands for RAS0 and RAS1. CASx stands for CAS0 and CAS1.
MSW is bit 5 and BC[1:0] comprises bits 13–12 in the DRAMC register. When the table identifies these bits, the
sequence of their listed values corresponds to the sequence of timing data provided.
Table 19-14. LCD DRAM DMA Cycle 16-Bit Fast Page Mode Access (LCD Bus Master)
Timing Parameters (Continued)
Number
Characteristic
(3.0 ± 0.3) V
Unit
Minimum
Maximum
LFLM
LD[7:0]
LLP
LCLK
3
4
1
2