Table 19-13. LCD DRAM DMA Cycle 16-Bit EDO RAM Mode Access (LCD Bus Master)
Timing Parameters
Number
Characteristic
(3.0 ± 0.3) V
Unit
Minimum
Maximum
1
Row address valid to RASx asserted
45
—
ns
2
DWE
negated before row address valid
0
—
ns
3
OE
asserted before RASx
asserted
0
—
ns
4
RASx asserted before row address invalid
(MSW = 0,1)
12,27
—
ns
5
Column address valid to CASx asserted
(MSW = 0,1)
10,25
—
ns
6
RASx asserted to CASx asserted (MSW = 0,1)
28,58
—
ns
7
CASx asserted to data-in valid
—
20
ns
8
CASx asserted before column address invalid
20
—
ns
9
RASX pulse width
(2N + 1)T
—
ns
10
CASx
pulse width
28
—
ns
11
CASx
precharge time
26
—
ns
12
RASx negated to CASx negated
-28
—
ns
13
Data-in hold after CASx
negated
30
—
ns
14
OE negated after CASx
negated
28
32
ns
Note:
N is the number of words in one DMA transfer.
T is the system clock period.
RASx stands for RAS0 and RAS1. CASx stands for CAS0 and CAS1.
MSW is bit 5 in the DRAMC register. When this bit is set to 0, the first timing number applies; when it is set to 1, the