band-mod

Bit 0, 1: Tx Cfg band

1- All tones on

2- All tones below 640 Khz are turned off

3- All tones below 1.1 Mhz are turned off

Bit 2,3: Not used

Bit 4,5: Rx Cfg band

1- All tones on

2- All tones below 640 Khz are turned off

3- All tones below 1.1 Mhz are turned off

Bit 6, 7:Optional band

0- No Optional band

1- ANNEX_A_6_32 ( ie. 25KHz to 138 KHz)

2- ANNEX_B_32_64 (ie. 138 KHz to 276 KHz)

3- ANNEX_B_6_64 (ie. 25KHz to 276 KHz)

port-option

Bit [0]: I 43 G.hs carrier set.

Bit [1]: V 43 G.hs carrier set.

Bit [2]. A 43 G.hs carrier set.

Bit [3]: B 43 G.hs carrier set.

Bit[4:7]: shall be set to 0.

power-mode

0: 8.5dBm power output

1: 11.5 dBm power output

tx-filter

0: using internal filter in Tx path

1: using K1 external filter in Tx path

(for Korea VLR Application)

2: using U1 external filter in Tx path

(for US / Korea VLR Application)

3: using H1 external filter in Tx path

(for 100/100 Application)

rx-filter

0: using internal filter in Rx path

1: using K1 external filter in Rx path

(for Korea VLR Application)

2: using U1 external filter in Rx path

(for US / Korea VLR Application)

3: using H1 external filter in Rx path

(for 100/100 Application)

dying-gasp

Dying Gasp is a message sent from CPE to CO using the indica-
tor bit. It indicates that the CPE is experiencing an impending
loss of power.

Off: Dying Gasp off (don't send a message to CO).

On: Dying Gasp on.

VDSL Parameters Accepted Values

Parameter