FUJITSU M3093DG User Manual
Page 90

The value of M3093DG back>side reading must be 0 or the same value as
front>side. Otherwise, the above error information may be returned.
(d) Upper left X, Y (ULX, ULY) : Bytes 6 to 9, A to D
Specified here are the X and Y coordinates of the upper>left corner of the
window. The coordinates are expressed in units of 1/1200 inches relative to
the upper>left corner of the maximum scan area.
If the ULX or ULY value is outside the maximum scan area of this scanner,
this scanner returns the following error information:
f
Status:
B©00001π (CHECK CONDITION)
f
Sense key: X©5π (ILLEGAL REQUEST)
(e) Width, length (W, L) : Bytes E to 11, 12 to 15
Specifies here are the width and length of the window, in units of 1/1200
inches. If the W or L value is outside the maximum scan area of this
scanner, the following error information is returned:
f
Status:
B©00001π (CHECK CONDITION)
f
Sense key: X©5π (ILLEGAL REQUEST)
The same error is also returned if this scanner is set to less than one raster
line for vertical scanning or to less than two bytes for horizontal scanning.
Notes:
1. ULX, ULY, W, L versus maximum scan area:
0 < (ULX + W) e 14592 (in 1/1200 inches) (M3096GX)
e 10368 (in 1/1200 inches) (M3093GX)
e 10368 (in 1/1200 inches) (M3093DG)
0 < (ULY + L) e 20736 (in 1/1200 inches) (M3096GX)
e 16800 (in 1/1200 inches) (M3093GX/DG)
2. Conditions for horizontal scanning:
9 e [XR ¥ W/1200] e 4864 (dot) (M3096GX)
e 3456 (dot) (M3093GX)
e 3456 (dot) (M3093DG without option)
e 5184 (dot) (M3093DG with memory option)
e 6912 (dot) (M3093DG with memory and
IPC>2D option)
(Values under 0 in [ ] are omitted.)
4 $ 58