4.4.14 SCAN

The normal SCAN sequence for the scanner is as follows:

Step

Bus phase

Initiator operation

¨Æ

Target operation

1

2

3

4

5

6

7

8

9

Bus Free

(Arbitration)

Selection

(Message Out)

Command

Data Out

Status

Message In

Bus Free

Checks Bus Free

Acquires the right to use the
bus

Selects the target

Selects the logical device

Specifies SCAN (CDB)

Specifies the window ID

Ж

Ж

Ж

Ж

¨

¨

Drives the BSY signal

Specifies reading

Reports GOOD status

Reports message
(Command complete)

Releases the BSY
signal

(1)

SCAN command: Command phase (Initiator to Target)

The SCAN command defines reading method for the scanner.

The command descriptor block (CDB) is as follows:

Byte 0

1

2

3

4

5

Operation code X©1Bπ

Logical unit number

7

6

5

4

3

2

1

0

(Reserved)

Control byte

(Reserved)

Allocation length

f

Transfer length: Byte 4

The transfer length specifies the number of bytes of window data sent during
the DATA OUT phase. A 0 means that no data is transferred. This is not an
error.

4 $ 108