Main memory

9.4

Replacing a faulty memory module

9.4.1

Required tools

Starting and completing the task:

key for the rack doors (if applicable)

Phillips Ph2 screw driver

Replacing the DIMM memory module: tool-less

9.4.2

Starting the task

Ê

Perform the following procedures:

1.

"Opening the rack door" on page 40

2.

"Locate the faulty server" on page 37

3.

"Shutting down the server" on page 41

4.

"Sliding the server out of the rack" on page 42

Authorized personnel

Authorized specialist personnel can carry out replacement tasks for
integral server components. Ask you local Fujitsu service center for
more detailed information.

V

CAUTION!

Procedures indicated as "Authorized personnel only“ must be
done by Fujitsu service personnel or technicians trained by
Fujitsu for doing these tasks. Please note that unauthorized
interference with the system will void the warranty and exempt the
manufacturer from all liability.