Panel settings menu – FUJITSU PRIMERGY BX600 User Manual
Page 78
Panel Settings Menu
Web-Based Management Interface
Intelligent Blade Panel Module
77
Viewing SNTP Global Status Page
Non-Configurable Data
Version
- Specifies the SNTP Version the client supports.
Supported Mode
- Specifies the SNTP modes the client supports. Multiple modes may
be supported by a client.
Last Update Time
- Specifies the local date and time (UTC) the SNTP client last updated
the system clock.
Last Attempt Time
- Specifies the local date and time (UTC) of the last SNTP request or
receipt of an unsolicited message.
Last Attempt Status
- Specifies the status of the last SNTP request or unsolicited
message for both unicast and broadcast modes. If no message has been received from a
server, a status of Other is displayed. These values are appropriate for all operational
modes.
•
Other
None of the following enumeration values.
•
Success
The SNTP operation was successful and the system time was
updated.
•
Request Timed Out
A directed SNTP request timed out without receiving a
response from the SNTP server.
•
Bad Date Encoded
The time provided by the SNTP server is not valid.
•
Version Not Supported
TheSNTP version supported by the server is not
compatible with the version supported by the client.
•
Server Unsychronized
The SNTP server is not synchronized with its peers.
This is indicated via the 'leap indicator' field on the SNTP message.
•
Server Kiss Of Death
The SNTP server indicated that no further queries were
to be sent to this server. This is indicated by a stratum field equal to 0 in a message
received from a server.
Server IP Address
- Specifies the IP address of the server for the last received valid
packet. If no message has been received from any server, an empty string is shown.