Accessing the Management Interface Troubleshooting and Tips
Intelligent Blade Panel Module
287
10.2 Accessing the Management Interface
You can access the management interface for the IBP from anywhere within the attached
network using Telnet, a Web browser, or any SNMP-based network management software. If
you are having trouble accessing the management interface, then refer to the troubleshooting
information displayed in the following table.
Symptom
Action
Cannot connect to the
IBP using Telnet, Web
browser, or SNMP
software
• Be sure you have configured the agent with a valid IP address,
subnet mask and default gateway.
• If you are trying to connect to the agent via the IP address for a
tagged VLAN group, your management station must include the
appropriate tag in its transmitted frames.
• Check that you have a valid network connection to the IBP
and that the port you are using has not been disabled.
• Check network cabling between the management station and the
IBP.
• If you cannot connect using Telnet, there may already be four
active sessions. Try connecting again at a later time.
Cannot access the
on-board
configuration program
via
a
serial
port
connection
• Be sure you have set the terminal emulator program to VT100
compatible, 8 data bits, 1 stop bit, no parity, and 19200 bps.
• Check that the null-modem serial cable conforms to the pin-out
connections provided in the Operating Manual for the server.
Forgot or lost the
password
• Restore the “Factory_Default_Config.cfg” file with the “boot
system” command described on page 134.