System

Maintenance

FortiAnalyzer Version 3.0 MR7 Administration Guide
05-30007-0082-20080908

71

FortiGuard Center

You can update the engine and vulnerability scan modules in one of the following
ways:

• manually upload update packages to the FortiAnalyzer unit from your

management computer

• configure the FortiAnalyzer unit to periodically request updates from the

Fortinet Distribution Network (FDN)

You must first register the FortiAnalyzer unit with the Fortinet Technical Support
web site,

https://support.fortinet.com/

to receive RVS updates from the FDN. The

FortiAnalyzer unit must also have a valid Fortinet Technical Support contract,
which includes RVS update subscriptions, and be able to connect to the FDN or
the IP address that you have configured to override the default FDN addresses.
For port numbers required for license validation and update connections, see the
Fortinet Knowledge Center article

FDN Services and Ports

.

For more information about configuring vulnerability scan jobs and viewing
vulnerability scan reports, see

“Tools” on page 157

.

To manually upload RVS updates or to configure scheduled RVS updates, go to
System > Maintenance > FortiGuard Center.

Encrypt configuration
file

Select to encrypt the backup file. Enter a password in the

Password field and enter it again in the Confirm field. You

will need this password to restore the file.
You must encrypt the backup file if you are using a

secure connection to a FortiGate or FortiManager device.

Backup

Select to back up the configuration.

Restore

Restore the configuration from a file.

Restore configuration
from:

Currently the only option is to restore from a PC.

Filename

Enter the configuration file name or use the Browse

button if you are restoring the configuration from a file on

the management. computer.

Password

Enter the password if the backup file is encrypted.

Restore

Select to restore the configuration from the selected file.

Firmware

Partition

A partition can contain one version of the firmware and

the system configuration.

Active

A green check mark indicates which partition contains the

firmware and configuration currently in use.

Last Upgrade

The date and time of the last update to this partition.

Firmware Version

The version and build number of the FortiAnalyzer

firmware. On the backup partition, you can:

Select Upload to replace with firmware from the
management computer.

Select Upload and Reboot to replace the firmware.