Figure 3-6. Install Device

7 . Use 2 supplied screws (SC-M4

×

14 .5TP10-SUS) to secure the device and

the mounting plate .

NOTE

When the screw’s head is beneath the device surface, the device is

secured.

Figure 3-7. Secure Device

NOTE

The installation height here is the recommended height. You can

change it according to your actual needs.

For easy installation, drill holes on mounting surface according to the

supplied mounting template.

C H AP T E R 4 . W I R I N G

You can connect the RS-485 terminal with the RS-485 card reader, connect

the NC and COM terminal with the door lock, connect the SENSOR terminal

with the door contact, the BTN/GND terminal with the exit button, connect the

alarm output and input terminal with the alarm output/input devices, and con-

nect the Wiegand terminal with the Wiegand card reader or the access con-

troller .

If connect the WIEGAND terminal with the access controller, the face recog-

nition terminal can transmit the authentication information to the access con-

troller and the access controller can judge whether to open the door or not .

NOTE

If cable size is 18 AWG, you should use a 12 V power supply. And the

distance between the power supply and the device should be no more

than 20 m.

If the cable size is 15 AWG, you should use a 12 V power supply. And the

distance between the power supply and the device should be no more

than 30 m.