beautypg.com

ATN TITEW1000 Thermal Entry Wizard Access Control Station with Table Stand Mount User Manual

Page 41

background image

80

81

Face 1:N Matching Threshold

Set the matching threshold when authenticating via 1:N matching mode . The

larger the value, the smaller the false accept rate and the larger the false rejec-

tion rate when authentication .

Face Recognition Interval

The time interval between two continuous face recognitions when authenti-

cating . By default, it is 2s .

Face Anti-spoofing

Enable or disable the live face detection function . If enabling the function,

the device can recognize whether the person is a live one or not .

Face 1:1 Matching Threshold

Set the matching threshold when authenticating via 1:1 matching mode . The

larger the value, the smaller the false accept rate and the larger the false rejec-

tion rate when authentication .

Application Mode

You can select indoor or others application modes according to actual envi-

ronment .

Lock Authentication Failed Face

After enabling the Live Face Detection function, the system will lock the us-

er's face for 5 minutes if the live face detection is failed for more than the con-

figured attempts . The same user cannot authenticate via the fake face within 5

minutes . Within the 5 minutes, the user can authenticate via the real face twice

continuously to unlock .

Liveness Detection Security Level

After enabling Live Face Detection function, you can set the matching secu-

rity level when performing live face authentication .

4 . Click OK .
5 . Optional: Click Copy to, and then select the card reader(s) to copy the pa-

rameters in the page to the selected card reader(s) .

Configure Parameters for Alarm Output

After adding the access control device, if the device links to alarm outputs,

you can configure the parameters .

Steps

1 . Click Access Control

Advanced Function

Device Parameter to enter

access control parameter configuration page .

2 . In the device list on the left, click to expand the door, select an alarm input

and you can edit the alarm input's parameters on the right .

3 . Set the alarm output parameters .

Name

Edit the card reader name as desired .

Alarm Output Active Time

How long the alarm output will last after triggered .
4 . Click OK .
5 . Optional: Set the switch on the upper right corner to ON to trigger the

alarm output .

7.6.2. Configure Multi-Factor Authentication

You can manage the persons by group and set the authentication for multi-

ple persons of one access control point (door) .

Before You Start

Set access group and apply the access group to the access control device .

For details, refer to Set Access Group to Assign Access Authorization to Per-

sons .

Perform this task when you want to set authentications for multiple cards of

one access control point (door) .

Steps

1 . Click Access Control

Advanced Function

Multi-Factor Auth .

2 . Select an access control device in device list on the left panel .
3 . Add a person/card group for the access control device .

a) Click Add on the right panel .
b) Create a name for the group as desired .
c) Specify the start time and end time of the effective period for the per-

son/card group .

d) Select members(s) and card(s) in the Available list, and the selected

member(s) and card(s) will be added to the Selected list .

NOTE

Make sure you have issue card to the person.
Make sure you have set access group and apply the access group to the

access control device successfully.

e) Click Save .
f) Optional: Select the person/card group(s), and then click Delete to de-

lete it(them) .

g) Optional: Select the person/card group(s), and then click Apply to

re-apply access group that failed to be applied previously to the access

control device .

4 . Select an access control point (door) of selected device on the left panel .
5 . Enter the maximum interval when entering password .
6 . Add an authentication group for the selected access control point .

a) Click Add on the Authentication Groups panel .
b) Select a configured template as the authentication template from the

drop-down list .

NOTE

For setting the template, refer to Configure Schedule and Template.

c) Select the authentication type as Local Authentication, Local Authenti-

cation and Remotely Open Door, or Local Authentication and Super Pass-

word from the drop-down list .

Local Authentication

Authentication by the access control device .

Local Authentication and Remotely Open Door

Authentication by the access control device and by the client . When the per-

son swipes the card on the device, a window will pop up . You can unlock the

door via the client .