beautypg.com

Terminal description, Wire normal device – ATN TITEW1000 Thermal Entry Wizard Access Control Station with Table Stand Mount User Manual

Page 10

background image

18

19

If the cable size is 12 AWG, you should use a 12 V power supply. And the

distance between the power supply and the device should be no more

than 40 m.

4.1. TERMINAL DESCRIPTION

The terminals contains power input, alarm input, alarm output, RS-485, Wie-

gand output, and door lock .

The terminal’s diagram is as follows:

Figure 4-1. Terminal Diagram

The descriptions of the terminals are as follows:

Table 4-1. Terminal Descriptions

Group

No.

Function

Color

Name

Description

Group A

A1

Power Input

Red

+12 V

12 VDC Power Supply

A2

Black

GND

Ground

Group B

B1

Alarm Input

Yellow/Blue

IN1

Alarm Input 1

B2

Yellow/Black

GND

Ground

B3

Yellow/Orange

IN2

Alarm Input 2

B4

Alarm Output

Yellow/Purple

NC

Alarm Output

B5

Yellow/Brown

COM

Wiring

B6

Yellow/Red

NO

Group C

C1

RS-485

Yellow

485+

RS-485 Wiring

C2

Blue

485-

C3

Black

GND

Ground

C4

Wiegand

Green

W0

Wiegand Wiring 0

C5

White

W1

Wiegand Wiring 1

C6

Brown

WG_OK

Wiegand Authenticated

C7

Orange

WG_ERR Wiegand Authentication Failed

C8

Purple

BUZZER

Buzzer Wiring

C9

Gray

TAMPER

Tampering Alarm Wiring

Group D

D1

Door Lock

White/Purple

NC

Lock Wiring (NC)

D2

White/Yellow

COM

Common

D3

White/Red

NO

Lock Wiring (NO)

D4

Yellow/Green

SENSOR

Door Contact

D5

Yellow/Gray

BTN

Exit Door Wiring

4.2. WIRE NORMAL DEVICE

You can connect the terminal with normal peripherals .
Follow the diagram below to wire the thermographic module and the device

main body:

The wiring diagram without secure door control unit is as follows .