NOTE

You should set the face recognition terminal’s Wiegand direction to

“Input” to connect to a Wiegand card reader. If connects to an access

controller, you should set the Wiegand direction to “Output” to transmit

authentication information to the access controller.

For details about Wiegand direction settings, see Setting Wiegand

Parameters in Communication Settings.

The power supply for the device should be 12 V DC, 2 A. The suggested

external power supply for door lock is 12 V, 1 A. The suggested external

power supply for the Wiegand card reader is 12 V, 1A.

The suggested power cable’s diameter: 22 AWG. The suggested other

cable’s diameter: 26 AWG.

Do not wire the device to the electric supply directly.

WARNING

The face recognition terminal shall adapt an external listed Class 2

power supply with surge protected function.

4.3. WIRE SECURE DOOR CONTROL UNIT

You can connect the terminal with the secure door control unit .
The wiring diagram is as follows .

Figure 4-3. Secure Door Control Unit Wiring

NOTE

The secure door control unit should connect to an external power

supply separately. The suggested external power supply is 12 V, 0.5 A.

4.4. WIRE FIRE MODULE

4.4.1. Wiring Diagram of Door Open When Powering Off

Lock Type: Anode Lock, Magnetic Lock, and Electric Bolt (NO)
Security Type: Door Open When Powering Off
Scenario: Installed in Fire Engine Access

Type 1

NOTE

The fire system controls the power supply of the access control system.