103

DHCP

If you disable the function, you should manually set the device's IPv4 ad-

dress, IPv4 subnet mask, IPv4 default gateway, MTU, and port .

If you enable the function, the system will automatically assign IPv4 address,

IPv4 subnet mask, IPv4 default gateway for the device .

HTTP

Set the HTTP port, DNS1 server address, and DNS2 server address .

7.10.8. Report Strategy Settings

You can set the center group for uploading the log via the EHome protocol .

On the Device for Management page, click

Network

Report Strate-

gy to enter the Report Strategy Settings tab .

You can set the center group and the system will transfer logs via EHome

protocol . Click Save to save the settings .

Center Group

Select a center group from the drop-down list .

Main Channel

The device will communicate with the center via the main channel .

NOTE

N1 refers to wired network.

7.10.9. Network Center Parameters Settings

You can set the notify surveillance center, center's IP address, the port No .,

the protocol (EHome), the EHome account user name, etc . to transmit data via

EHome protocol .

On the Device for Management page, click

Network

Network Cen-

ter Parameters to enter the Network Center Parameters Settings tab .

Select a center from the drop-down list .
After enabling the function, you can set the center's address type, IP ad-

dress/domain name, port No ., EHome user name, etc .

Click Save .

7.10.10. Configure SIP Parameters

Set the master station's IP address and the SIP server's IP address . After

setting the parameters, you can communicate among the access control de-

vice, door station, indoor station, master station, and the platform .

NOTE

Only the access control device and other devices or systems (such as

door station, indoor station, master station, platform) are in the same IP

segment, the two-way audio can be performed.

Click Maintenance and Management

Device to enter the device list .

Click

to enter the remote configuration page .

Click Network

Linked Network Configuration and set the master station's

IP address and SIP server's IP address .

Click Save .

7.10.11. Set Relay Parameters

Click Maintenance and Management

Device to enter the device list .

Click

to enter the remote configuration page .

Click Alarm

Relay . Select a relay and click

and set the relay name and

output delay time . Click OK to save the settings .

7.10.12. Set Access Control Parameters

Steps

1 . On the Device for Management page, click

Others

Access Con-

trol Parameters to enter the Access Control Parameters tab .

2 . Check the checkbox to enable the function .

Voice Prompt

If you enable this function, the voice prompt is enabled in the device . You

can hear the voice prompt when operating in the device .

Upload Pictures after Capturing

If you enable this function, the captured pictures will be sent to the client

software .

Save Captured Pictures

If you enable this function, the captured pictures will be saved .
3 . Click Save .

7.10.13. Set Face Recognition Terminal Parameters

Click Maintenance and Management

Device to enter the device list .

Press CTRL and click

to enter the remote configuration page .

Click Other

Face Recognition Terminal Parameters and you can config-

ure the device parameters .

Face Picture Database

Select Deep Learning as the face picture database .

Save Authenticating Face Picture

If enabled, the captured face picture when authenticating will be saved on

the device .

CPU Card Reading

Select to read card No . or file .

Work Mode

Set the device work mode as Normal Mode . You should authenticate your

credential for accessing .

ECO Mode

After enabling the ECO mode, the device will use the IR camera to authenti-

cate faces in the low light or dark environment . And you can set he ECO mode

threshold, ECO mode (1:N), and ECO mode (1:1) .

ECO Mode (1:1)

Set the matching threshold when authenticating via ECO mode 1:1 match-

ing mode . The larger the value, the smaller the false accept rate and the larg-

er the false rejection rate .

ECO Mode (1:N)