beautypg.com

Set access control parameters – ATN TITEW1000 Thermal Entry Wizard Access Control Station with Table Stand Mount User Manual

Page 23

background image

44

45

Table 6-3. Face Picture Parameters

Parameter

Description

1:N (Security) Level

Set the matching threshold when authenticating via 1:N

matching mode . The larger the value, the smaller the false

accept rate and the larger the false rejection rate . By default,

the value is 84 .

1:1 (Security) Level

Set the matching threshold when authenticating via 1:1

matching mode . The larger the value, the smaller the false

accept rate and the larger the false rejection rate . By default,

the value is 75 .

Recognition

Interval

Set the time interval between two continuous face

recognitions when authenticating one person's permission .

NOTE

You can enter the number from 1 to 10.

Liveness Level

(Liveness Security

Level)

After enabling Live Face Detection function, you can set

the matching security level when performing live face

authentication .

WDR Level

The device can auto enable the WDR function . The higher

the level, the device can enter the WDR mode easier . 0

represents WDR is disabled .

Pupillary Distance

The minimum resolution between two pupils when starting

face recognition . The actual resolution should be larger than

the configured value .

By default, the resolution is 40 .

Face with Mask

Detection

After enabling this function, when a person authenticates

the permissions on the authentication page, the device

can recognize the face whether wearing a mask or not, and

prompts to wear a mask according to the configuration .

Face with Mask &

Face with Mask

(1:N)

Matching threshold for face with mask 1 : N . The larger the

value, the smaller the false accept rate and the larger the

false rejection rate . The Max . value is 100 .

Must Wear Face

Mask

After enabling this function, the authenticated person must

wear a face mask, otherwise the authentication will be failed .

Reminder of

Wearing Face Mask

After enabling this function, if the authenticated person does

not wear a face mask, a prompt will be pop-up to remind you

to wear a face mask .

ECO Mode

After enabling the ECO mode, the device will use the

IR camera to authenticate faces in the low light or dark

environment . And you can set he ECO mode threshold, ECO

mode (1:N), and ECO mode (1:1) .

ECO Mode

Threshold

When enabling the ECO mode, you can set the ECO mode’s

threshold . The larger the value, the easier the device

entering the ECO mode . Available range: 0 to 8 .

ECO Mode (1:N)

Set the matching threshold when authenticating via ECO

mode 1:N matching mode . The larger the value, the smaller

the false accept rate and the larger the false rejection rate .

By default, the value is 84 .

ECO Mode (1:1)

Set the matching threshold when authenticating via ECO

mode 1:1 matching mode . The larger the value, the smaller

the false accept rate and the larger the false rejection rate .

By default, the value is 75 .

Face with

Mask&Face (1:N)

(ECO)

Matching threshold for face with mask 1: N in ECO mode .

The larger the value, the smaller the false accept rate and

the larger the false rejection rate . The Max . value is 100 .

6.8.3. Set Time

You can set the device time and the DST in this section .
Tap Time (Time Settings) on the Home page to enter the Time Settings

page . Edit the time parameters and tap

to save the settings .

Figure 6-12. Time Parameters

6.9. SET ACCESS CONTROL PARAMETERS

You can set the access control permissions, including the functions of ter-

minal auth . mode, reader auth . mode, QR code, remote authentication, door

contact, and door locked time, etc .

On the Home page, tap ACS (Access Control Settings) to enter the Access

Control Settings page . Edit the access control parameters on this page and
tap