Table 2-1. Description of Face Recognition Terminal

No.

Name

1

USB Interface

2

Card Swiping Area

3

Touch Screen

4

Camera

5

IR Light

6

White Light

7

Thermographic Module

8

IR Light

9

Camera

10

TAMPER

11

Thermographic Module Interface

12

Debugging Port

13

Power Interface

14

Wiring Terminals

15

PSAM Card Slot (Reserved)

16

Network Interface

C H AP T E R 3 . I N S TA LL AT I O N

3.1. INSTALLATION ENVIRONMENT

• Avoid backlight, direct sunlight, and indirect sunlight .
• For better recognition, there should be light source in or near the installa-

tion environment .

• Indoor and windless environment use only .

NOTE

For details about installation environment, see Tips for Installation

Environment.

3.2. FLUSH MOUNTING

Steps

1 . Install a gang box .
2 . Connect the thermographic module and the main body .

Figure 3-1. Connect Thermographic Module

3 . Use 5 supplied screws (4_KA4

×

22-SUS) to secure the mounting plate on

the gang box .

4 . Route the cable through the cable hole of the mounting plate and connect

to corresponding external devices’ cables .

5 . Align the device with the mounting plate and hang the device on the

mounting plate . Make sure the two sheets on each side of the mounting

plate have been in the slots at the back of the device .

Figure 3-2. Install Device