Output parameters, Standard function blocks sb059 – Pilz PSS SB HYD, Basic license User Manual

Page 82

background image

6-20

Modular Block System: Hydraulic Presses

Standard Function Blocks

SB059

INFORMATION
• All two-hand buttons must use test pulses. These pulses should be

entered in the configurator (DB 002) accordingly.

• Ensure the selector switch contact for input parameter

Off has a test

pulse output and enter this output in the configurator (DB 002)
accordingly

• If the block is to be used to monitor a foot switch, the inputs of the N/O

and N/C contacts on the foot switch must be connected to

T1.2 and T2.2

or

T1.4 and T2.4 respectively.

• In accordance with EN 574 section 3.5, 02/97, monitoring of the

synchronisation time between the two buttons is set at < 0.5 s.

Output parameters

• FG:

Enable flag bit
FG = 0:

Not enabled

FG = 1:

Two-hand operation is enabled
Two-hand operation is enabled provided the
output parameter

STFG = 1, both buttons (T1 and

T2) are operated within 0.5 s and any errors have
been rectified and reset.

GST:

Start position
GST = 0:

T1 and T2 not in start position

GST = 1:

Both buttons (T1 and T2) are released.

AUF:

(for use only with hydraulic presses)
AUF = 0:

“Upward movement with one button” is inactive

AUF = 1:

Only one button needs to be operated for longer
than 0.5 s to trigger an upward movement.

This output may only move the press slide upwards. Ejectors
and die cushions may only be moved to TDC using a separate
button.

OFF:

Two-hand control circuit/console is selected/deselected
(input parameter

Off)

OFF = 0:

Two-hand control circuit/console selected (

Off = 0)

OFF = 1:

Two-hand control circuit is correctly deselected
(

Off = 1) and disconnected.