Modular Block System: Hydraulic Presses

• Block enable

- If the input parameters

NO_1 and NO_2 return to a 1-signal within the

maximum permitted reaction time, the block enable will be triggered
(output parameter

ENBL = 1). This means that the automatic function

test of the ESPE/AOPD has been completed successfully.
The maximum permitted duration of the whole test on Type 2 ESPE/
AOPDs is 150 ms (in accordance with EN 61 496-1 Section 5.2.4, 06/
98).

- If the ESPE/AOPD does not react within the permitted time, the block

enable on the ESPE/AOPD will remain locked (output parameter
ENBL = 0). An error message will appear (see also under “Error
messages” in the SB068 description).

Setting the block parameters

KB1

- SSNR

ESPE-N/O1

- NO_1

ESPE-N/O2

- NO_2

OFF mode = 0

OFF

GdO mode = 1

GdO

SBrk mode = 0

SBrk

DBrk mode = 0

DBrk

Press-ON

- RUN

M 110.00 (RLO-0)

- CyRs

M 110.00 (RLO-0)

- SSeq

M 110.00 (RLO-0)

- ARSt

M 110.00 (RLO-0)

- STyp

UN-signal

- Test

Reset button

- RSET

SB068

BWS_AOS

ENBL - ESPE enabled
TEST - Test input of ESPE emitter
RdCy - Ready to cycle
PWR

- Voltage supply to ESPE