6-18

Modular Block System: Hydraulic Presses

Standard Function Blocks

Tipp = 1:

Mode: “Jog mode using one button” is permitted.
The input should be assigned the flag “Setup
mode”.
The input parameter

Tipp = 1 has no effect on

normal two-hand operation. However, jog mode
using one button, where the other button is
constantly operated, is additionally permitted.

Procedure:
To start jog mode, press both two-hand buttons
simultaneously, then release one button while the keeping the
other pressed down. Operate jog mode using the two-hand
button that was released.

WARNING!
The input parameter

Auf is intended exclusively for use on hydraulic

presses. It must not be activated on eccentric presses.
On eccentric presses, this input should be assigned RLO-0 (M110.00).

Auf:

Activate upward movement with one button (output parameter
AUF)
Auf = 0:

Output parameter

AUF is inactive (AUF = 0)

Assign the input RLO-0 (M110.00) if you want to
use both buttons to activate the upward
movement.

Auf = 1:

Output parameter

AUF is set (AUF = 1), if one

button is operated for longer than 0.5 s
Assign the input RLO-1 (M110.01) if you want to
use one button to activate the upward movement.

Off:

Deselect two-hand control circuit
Where plug-in two-hand devices/consoles are being
monitored, there is the option to deselect a two-hand device/
console (e.g. re-tooling to two-man operation from 4-man).
Off = 0:

Two-hand control circuit/console is selected

Off = 1:

Two-hand control circuit/console is deselected

SB059