Page 177: Machine halted (input parameter mrun)
Modular Block System: Hydraulic Presses
6-115
Procedures
Unlock
If a request is made to open the gate (
RQST = 0/1 pulse edge) when the
gate is locked, the request will not be performed until the hazardous
machine functions have stopped (
STPD = 0/1 pulse edge).
Only then will the enable output be reset (if it was set) and the gate
unlocked (
UNLK = 1). The gate can then be opened.
Lock
If a request is made to lock the gate (
RQST = 0/1 pulse edge) when the
gate is closed but not yet locked, the gate will be locked (
UNLK = 0). When
the gate is locked (
LCKD = 1), the enable will be set directly (ARSt = 1) or
after a reset (
ARSt = 0), provided no other errors are present.
If a request is made to lock the gate (
RQST = 0/1 pulse edge) when the
gate is still open, the gate will remain unlocked and an error message will
be triggered (see section entitled “Error messages”).
Machine halted (input parameter
MRun)
A function test can be triggered via this parameter: When the machine is
halted (MRun = 1/0 pulse edge), the enable is reset directly. As soon as
the hazardous machine functions have stopped, the gate is unlocked
(
UNLK = 1) and the operator is prompted to carry out a function test (see
section entitled “Error messages”). This function is independent of the
input parameter
NoFT.
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license