beautypg.com

Procedures, Unlock, Lock – Pilz PSS SB HYD, Basic license User Manual

Page 177: Machine halted (input parameter mrun)

background image

Modular Block System: Hydraulic Presses

6-115

Procedures

Unlock

If a request is made to open the gate (

RQST = 0/1 pulse edge) when the

gate is locked, the request will not be performed until the hazardous
machine functions have stopped (

STPD = 0/1 pulse edge).

Only then will the enable output be reset (if it was set) and the gate
unlocked (

UNLK = 1). The gate can then be opened.

Lock

If a request is made to lock the gate (

RQST = 0/1 pulse edge) when the

gate is closed but not yet locked, the gate will be locked (

UNLK = 0). When

the gate is locked (

LCKD = 1), the enable will be set directly (ARSt = 1) or

after a reset (

ARSt = 0), provided no other errors are present.

If a request is made to lock the gate (

RQST = 0/1 pulse edge) when the

gate is still open, the gate will remain unlocked and an error message will
be triggered (see section entitled “Error messages”).

Machine halted (input parameter

MRun)

A function test can be triggered via this parameter: When the machine is
halted (MRun = 1/0 pulse edge), the enable is reset directly. As soon as
the hazardous machine functions have stopped, the gate is unlocked
(

UNLK = 1) and the operator is prompted to carry out a function test (see

section entitled “Error messages”). This function is independent of the
input parameter

NoFT.