Modular Block System: Hydraulic Presses

Standard Function Blocks

SB072

- the ESPE/AOPD for t >

TInt is released or

- before

TInt has elapsed, if there are no more muting signals.

When parallel muting is activated, a parallel muting signal
(MP1 or MP2) may be released for the time

TInt.

The released signal must be re-operated within the time
specified under

TInt, or the other signal must also be released.

Parallel muting is switched off when:
- the ESPE/AOPD for t >

TInt is released (when MP1 = MP2 =

0) or
- MP1 and MP2 are released when the ESPE/AOPD has
already been released (when the muting signal is arranged in
a cross/star formation)
In general, muting is switched off when there are no more
muting signals.

TMut :

Timer Muting
This setting determines the maximum permitted muting time.
Permitted value range: 0 ... 511 (^

= 8.5 minutes)

Format:

Word

Time unit:

s

TOPD:

Timer (active) Optoelectronic Protective Device
This setting determines the maximum time permitted between:
“Muting ON” and “ESPE/AOPD interrupted” and:
“Muting sensor exited” and “ESPE/AOPD released”.
The time elapsing between the start of muting and the
interruption of the ESPE/AOPD must not exceed t = TOPD.
The time elapsing between exiting the last muting switch and
the enabling of the ESPE/AOPD must not exceed t = 2 x
TOPD.
Permitted value range: 0 ... 8191
Format:

Word

Time unit:

ms

TOff :

Halt all muting timers
TOff = 0:

Muting timer active

TOff = 1:

Halt all muting timers

For example, this input parameter could be connected to the
signal “Conveyor stopped”.

AuSt:

Start-up disabler on PSS start-up
AuSt = 0:

Start-up disabler (reset required on PSS start-up)

AuSt = 1:

Automatic reset