Sb051: operating mode selector switch, 1 from 8, Block header, Input parameters – Pilz PSS SB HYD, Basic license User Manual
Page 68: Standard function blocks, Sb051
6-6
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB051: Operating mode selector switch, 1 from 8
Block header
Input parameters
•
SSNR:
Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).
•
S1 ... S8: Switch levels from operating mode selector switch
On each position of the selector switch, a 1-signal must be
present at one switch contact only.
Unused inputs should be assigned RLO-0 (M 110.00)
Input coding of selector switch (mode 1 from 8):
SB 051
BA_1AUS8
B - SSNR
X - S1
X - S2
X - S3
X - S4
X - S5
X - S6
X - S7
X - S8
X - RSet
X - LOCK
W - TIME
FG
- X
BA
- B
RSET - X
Position
S8
S7
S6
S5
S4
S3
S2
S1
Dec.Value
S1
1
0
0
0
0
0
0
0
1
1
2
0
0
0
0
0
0
1
0
2
3
0
0
0
0
0
1
0
0
4
4
0
0
0
0
1
0
0
0
8
5
0
0
0
1
0
0
0
0
16
6
0
0
1
0
0
0
0
0
32
7
0
1
0
0
0
0
0
0
64
8
1
0
0
0
0
0
0
0
128
SB051
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license