beautypg.com

Sb051: operating mode selector switch, 1 from 8, Block header, Input parameters – Pilz PSS SB HYD, Basic license User Manual

Page 68: Standard function blocks, Sb051

background image

6-6

Modular Block System: Hydraulic Presses

Standard Function Blocks

SB051: Operating mode selector switch, 1 from 8

Block header

Input parameters

SSNR:

Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).

S1 ... S8: Switch levels from operating mode selector switch

On each position of the selector switch, a 1-signal must be
present at one switch contact only.
Unused inputs should be assigned RLO-0 (M 110.00)

Input coding of selector switch (mode 1 from 8):

SB 051

BA_1AUS8

B - SSNR
X - S1
X - S2
X - S3
X - S4
X - S5
X - S6
X - S7
X - S8
X - RSet
X - LOCK
W - TIME

FG

- X

BA

- B

RSET - X

Position

S8

S7

S6

S5

S4

S3

S2

S1

Dec.Value

S1

1

0

0

0

0

0

0

0

1

1

2

0

0

0

0

0

0

1

0

2

3

0

0

0

0

0

1

0

0

4

4

0

0

0

0

1

0

0

0

8

5

0

0

0

1

0

0

0

0

16

6

0

0

1

0

0

0

0

0

32

7

0

1

0

0

0

0

0

0

64

8

1

0

0

0

0

0

0

0

128

SB051