background image

Modular Block System: Hydraulic Presses

6-125

MTi

RQST

STRT

ETP

TLS

ENBL

OK

Timing diagram

Error messages

Any fault that is detected will be stored in the corresponding error data
word (SSNR) of DB015 (1st data block), until the fault has been fully dealt
with.

• Bit 00:

Press is not at the extreme top position (ETP) when the

overrun measurement is started.
Remedy: Move press to extreme top position (ETP); check all
conditions, then reset (input parameter:

RSET), error resets

automatically at ETP

• Bit 01:

Overrun measurement is missing

• Bit 02:

Overrun measurement is running

• Bit 03:

Test cam (TLS: test limit switch) reached, withdraw START

command

• Bit 04:

Evaluation of overrun measurement is running, i.e. test cam

(TLS) reached, START command withdrawn and “MTi” time
not yet elapsed

• Bit 08:

Reset button constantly pressed or pressed too early.

Remedy: Release reset button, check all conditions (input
parameter:

RSET)