beautypg.com

Block header, Input parameters, Standard function blocks – Pilz PSS SB HYD, Basic license User Manual

Page 210: Sb089

background image

6-148

Modular Block System: Hydraulic Presses

Standard Function Blocks

SB089: Sequential driving/monitoring the position of two hydraulic
valves (poppet and directional control valves)

Block header

Input parameters

SSNR:

Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).
Value of DW (

SSNR) = 0: No error found

StEn:

Static enable for operating the valve
StEn = 0:

Valve operation disabled

StEn = 1:

Valve operation enabled

S1:

Valve 1: Acknowledgement of position
S1 = 1:

Start position of valve (valve de-energised,
acknowledgement from valve is present)

S2:

Valve 2: Acknowledgement of position
S2 = 1:

Start position of valve (valve de-energised,
acknowledgement from valve is present)

INFORMATION
If valves Y1 and Y2 are acknowledged via switches, the supply to these
switches must be from test pulses.

SB089

H_VALV_P

B - SSNR
X - StEn
X - S1
X - S2
W - TOn
W - TOff
X - Y1On
X - Y2On
X - VTyp
X - RSET

ENBL - X
Y1

- X

Y2

- X

ERR - X

SB089