Sb066: safety gate monitoring, Block header, Input parameters – Pilz PSS SB HYD, Basic license User Manual
Page 108: Standard function blocks, Sb066
6-46
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB066: Safety gate monitoring
Block header
Input parameters
•
SSNR:
Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).
•
S1:
Gate switch: Signal 1
•
S2:
Gate switch: Signal 2
•
SyTi:
Synchronisation time between S1 and S2
Value in ms [0 ... 30000]; 0 = infinite time; format: word
constants (KF)
•
MEin:
Machine is running
MEin = 0:
Machine standing
MEin = 1:
Machine running
MEin = 1/0-pulse edge: Activate reset lock
This parameter can force the operator to carry out a function
test of the gate (gate open/closed).
The reset lock is lifted by carrying out a function test on the
gate followed by the
Strt Signal.
•
Strt:
Reset input
Strt = 0/1-pulse edge:
- Reset errors OR
- Reset start-up disabler OR
- Reset reset lock
SB 066
ST_K4
B - SSNR
X - S1
X - S2
W - SyTi
X - MEin
X - Strt
X - ARSt
X - AuSt
X - NFkT
FG - X
SB066
If the gate is closed, both gate
switches must supply a 1-signal
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license