beautypg.com

Reset lock (input parameter arst) – Pilz PSS SB HYD, Basic license User Manual

Page 175

background image

Modular Block System: Hydraulic Presses

6-113

Yes

x

x

x

x

x

No

x

o

o

x

/

Yes

x

x

x

x

-

No

x

o

o

x

-

Yes

No

Reset lock (

ARSt

)

Function test required (

NoFT

)

Request (

RQST

)

Open gate

Close gate

Request (

RQST

)

Reset (

RSET

)

Reset lock (input parameter

ARSt)

If the reset lock is active (

ARSt = 0), you will need to reset after each

• Opening and subsequent closing/locking of the gate (not applicable if the

gate was not opened between unlocking and locking)

• Function test

• Error

Only then can the enable be given. If no other errors are present, the
enable will be set.

If the reset lock is not active (

ARSt = 1), the enable will be set directly,

without a reset, after the above situations.

Note: This procedure is independent of the status of the input parameter
AuSt

Key:
x:

Action must be performed

o:

Action can be performed

/ :

Action does not need to be performed if the gate was not open