Output parameters – Pilz PSS SB HYD, Basic license User Manual
Page 69
Modular Block System: Hydraulic Presses
6-7
•
RSet:
Reset input for error acknowledgement
RSet = 0/1 signal edge: Reset occurs
•
LOCK:
Lock switch position
LOCK = 0: Switch position unlocked
LOCK = 1: Switch position locked
If the switch position changes, an error will be
triggered immediately
The parameter
LOCK can be allocated the flag “Machine
running” or “press safety valve: on”, for example.
•
TIME:
Maximum permitted contact switchover time between two
correct switch positions
Permitted time range: 1 ... 2047 ms
INFORMATION
If possible you should use the PSS(1) DI2 as input module.
If this is not possbible, the inputs must use test pulses.
Output parameters
•
FG:
Enable flag bit
FG = 1:
Enabled (no errors)
i.e. existing errors were reset via
RSet and
only one input (
S1... S8) = 1.
•
BA:
Operating mode,
Output parameter: Byte format (8 Bit)
If the input signal is faulty, no bit will be set in output byte
BA.
Output coding of selector switch (mode 1 from 8):
Position
Output Parameter
BA (Byte Format)
Dec. Value
Bit: 07
06
05
04
03
02
01
00
1
0
0
0
0
0
0
0
1
1
2
0
0
0
0
0
0
1
0
2
3
0
0
0
0
0
1
0
0
4
4
0
0
0
0
1
0
0
0
8
5
0
0
0
1
0
0
0
0
16
6
0
0
1
0
0
0
0
0
32
7
0
1
0
0
0
0
0
0
64
8
1
0
0
0
0
0
0
0
128
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license