Output parameters – Pilz PSS SB HYD, Basic license User Manual

Page 69

background image

Modular Block System: Hydraulic Presses

6-7

RSet:

Reset input for error acknowledgement
RSet = 0/1 signal edge: Reset occurs

LOCK:

Lock switch position
LOCK = 0: Switch position unlocked
LOCK = 1: Switch position locked

If the switch position changes, an error will be
triggered immediately

The parameter

LOCK can be allocated the flag “Machine

running” or “press safety valve: on”, for example.

TIME:

Maximum permitted contact switchover time between two
correct switch positions
Permitted time range: 1 ... 2047 ms

INFORMATION

If possible you should use the PSS(1) DI2 as input module.
If this is not possbible, the inputs must use test pulses.

Output parameters

FG:

Enable flag bit
FG = 1:

Enabled (no errors)
i.e. existing errors were reset via

RSet and

only one input (

S1... S8) = 1.

BA:

Operating mode,
Output parameter: Byte format (8 Bit)
If the input signal is faulty, no bit will be set in output byte

BA.

Output coding of selector switch (mode 1 from 8):

Position

Output Parameter

BA (Byte Format)

Dec. Value

Bit: 07

06

05

04

03

02

01

00

1

0

0

0

0

0

0

0

1

1

2

0

0

0

0

0

0

1

0

2

3

0

0

0

0

0

1

0

0

4

4

0

0

0

0

1

0

0

0

8

5

0

0

0

1

0

0

0

0

16

6

0

0

1

0

0

0

0

0

32

7

0

1

0

0

0

0

0

0

64

8

1

0

0

0

0

0

0

0

128