Modular Block System: Hydraulic Presses
Standard Function Blocks
• Bit 09:
Error can only be reset at the extreme top position (ETP) of the
press.
Remedy: Move press to extreme top position (ETP); check all
conditions, error resets automatically at ETP
• Bit 10:
Press overrun is too long, i.e. the test cam (TLS) was passed
on the overrun measurement; the press is disabled.
Remedy: Move press to extreme top position (ETP); check all
conditions, then reset (input parameter:
RSET), repeat overrun
measurement
• Bit 11:
The signal from the test cam (TLS) is missing when starting
the overrun measurement from the extreme top position (ETP).
Remedy: Check all conditions, then reset (input parameter
RSET)
• Bit 12:
Test cam (TLS) reached and the extreme top position (ETP) is
still free.
Remedy: Move press to extreme top position (ETP); check all
conditions, then reset (input parameter:
RSET)
Global parameters used in the administration blocks
Global parameters are set in OB120 using SB071.
• DW 1022: Minimum PSS scan time
Blocks required
• DB015:
Administration data block
DB015 must consist of its total length of 1024 data words and
have READ/WRITE access (see section entitled
“Administration data blocks” in Chapter 5).
SB086
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license