6-80

Modular Block System: Hydraulic Presses

Standard Function Blocks

SB070

SB070: Initialisation of administration data block DB015

Block header

Input parameters

KoSy:

Contact synchronisation time of 2 N/O or N/C contacts

RRFK:

Reaction time feedback loop contactor

KU_S:

Contact switchover time N/O / N/C on buttons

KU_R:

Contact switchover time N/O / N/C on relays

MaZy:

Machine cycle time for cycling ESPE/AOPD

RBWS:

ESPE/AOPD reaction time

RVen:

Valve switchover time

Function

• Reads in the preset minimum scan time from DB002

A minimum scan time must always be configured if you are using MBS
blocks. Please refer to the section entitled “Minimum scan time” in
Chapter 5.

• Calculates the cycles using the times transferred in the parameters

• Enters the values into global parameters DW1001 ... DW1007 of

administration data block DB015.

SB 070

INIT_MBS

B - KoSy
B - RRFK
B - KU_S
B - KU_R
W - MaZy
B - RBWS